FILPURE® Outside-in Configuration UF series

Our, outside-in configuration series UF membranes are manufactured using REINFORCED PVDF (Polyethersulfone) chemistry, offering excellent chlorine tolerance, broad pH stability, and reliable long-term performance across demanding water and wastewater applications.

FILPURE® Ultrafiltration (UF) 2880/2860 module (OUTSIDE-IN)

Parameter Specification
Model Filpure-2880 / Filpure-2860
Membrane Type Hollow-fiber UF
Polymer Hydrophilic PVDF
Nominal pore size 0.03 µm
Flow configuration Outside-In
Membrane Area 77 m2 (829 ft2)/52 m2 (560 ft2)
Housing UPVC
S. N. Project FILPURE 2860
(52 m²)
FILPURE 2880
(77 m²)
1 Maximum length of membrane assembly L1 (mm) 1860 2360
2 Lawton height of membrane module L2 (mm) 1820 2330
3 Center distance of side orifice of membrane assembly L3 (mm) 1630 2130
4 Center distance of membrane module inlet L4 (mm) 95 95
5 Side port length of membrane assembly L5 (mm) 182.5 182.5
6 Membrane assembly diameter ⌀ (mm) 225 225
7 Packing area of membrane assembly (m²) 53 77
8 Wet weight of membrane assembly (Kg) 85 100
9 Transport weight of membrane module (Kg) 55 62
FILPURE OUTSIDE CONFIGURATION 2860-2880

Feed Water Specification

S.N. Parameters Unit Specification
1. Temperature °C Nominal 25 / Maximum 40
2. Particle size µ < 100
3. Turbidity NTU 50 (Max 300)
4. Oil & Grease Mg/l < 1
5. pH 6 ~ 9
5. TSS Mg/l 50 (Max 100)
6. Chlorine tolerance Mg/l 200 (Instant Max. 2000)

Module Specification

S.N. Parameters Unit Specification
1. Shell and Cap – U – PVC
2. Membrane Material of construction (MOC) – Modified PVDF
3. Membrane Type – Hollow Fiber
4. Connection MM DN 50
5. End Seal Material / Potting Material Polyurethane
6. Flow Direction – Outside to In
7. Inside / Outside Diameter of Fiber MM 0.7 / 1.2
8. Nominal MWCO Dalton 6000 ~ 1,50,000
9. Membrane Type – External Pressure / Forced Type
10. Nominal Membrane Pore Size µM 0.03

Operation

S.N. Parameters Unit Specification
1. Operation Mode – Dead End / Cross – Flow
2. Temperature °C 4 – 40
3. Filtrate Flux @ 25 °C L/M2/Hr. 40 ~ 120
4. Feed Water Pressure @ 25 °C Bar 2 ~ 3
5. Filtrate Water SDI < 3
6. Filtrate Water Turbidity NTU < 0.3

Cleaning Process

Parameters Specification
Backwash Backwash Frequency Every 30 Mins.
Backwash time 0.5 ~ 4 minutes per session
Backwashing water permeability rate 100 ~ 150 LMH
Maximum backwash pressure 2.5 bar
Flushing flow rate 100 m3/h
Flushing Time 20 – 30 seconds each time
Flushing Frequency Combined with operation and backwashing

Air scouring

Parameters Specification
Air Scouring Air per membrane element 5 ~ 7 Nm3/Hr.
Air scouring time 30 ~ 180 seconds each time
Air scouring frequency As and when required
Air scouring inlet pressure ≤ 1.0 Bar

FILPURE® ultrafiltration (UF) modules are manufactured using high-strength hollow-fiber membranes designed to provide reliable filtration performance, excellent chemical resistance, and long membrane service life.

Key features and benefits:

  • 0.03 µm nominal pore diameter — effectively removes bacteria, suspended particulates, and colloidal matter, helping protect downstream processes such as RO.
  • PVDF polymeric hollow fibers — provide high mechanical strength and excellent chemical resistance, supporting long-term membrane durability.
  • Hydrophilic PVDF fibers — provide good water wettability and facilitate effective membrane cleaning, helping maintain long-term filtration performance.
  • Outside-In flow configuration — provides high tolerance to feed solids and can help reduce the requirement for extensive pretreatment.
  • U-PVC module housing — provides a robust and corrosion-resistant housing while eliminating the need for costly external pressure vessels.

This UF modules are an ideal solution for medium- and large-capacity water-treatment systems, particularly systems with capacities above 50 m³/hr. They are suitable for a wide range of applications, including surface water treatment, industrial wastewater treatment, tertiary wastewater treatment, and pretreatment for reverse osmosis (RO) systems.

Ready for a better water treatment outcome?

Contact Us