FILPURE® ULTRA FILTRATION (UF) Solutions

FILPURE® Ultrafiltration (UF) membranes are an ideal choice for the effective retention of microorganisms, yeast, colloids, and suspended particles, while allowing salts, proteins, and other smaller organic molecules to pass through the membrane.

As part of our comprehensive ultrafiltration portfolio, we offer different FILPURE® UF series, each designed and optimized for specific applications and operating requirements.

FILPURE® offers uf in both type, outside-in configuration as well inside-out configuration and it provides precise control over the membrane fouling rate, helping maintain stable flux, extend membrane service life, and ensure consistent filtration performance.

FILPURE® Outside-in Configuration UF series

Our, outside-in configuration series UF membranes are manufactured using REINFORCED PVDF (Polyethersulfone) chemistry, offering excellent chlorine tolerance, broad pH stability, and reliable long-term performance across demanding water and wastewater applications.

FILPURE® Ultrafiltration (UF) 2880/2860 module (OUTSIDE-IN)

Parameter Specification
Model Filpure-2880 / Filpure-2860
Membrane Type Hollow-fiber UF
Polymer Hydrophilic PVDF
Nominal pore size 0.03 µm
Flow configuration Outside-In
Membrane Area 77 m2 (829 ft2)/52 m2 (560 ft2)
Housing UPVC
S. N. Project FILPURE 2860
(52 m²)
FILPURE 2880
(77 m²)
1 Maximum length of membrane assembly L1 (mm) 1860 2360
2 Lawton height of membrane module L2 (mm) 1820 2330
3 Center distance of side orifice of membrane assembly L3 (mm) 1630 2130
4 Center distance of membrane module inlet L4 (mm) 95 95
5 Side port length of membrane assembly L5 (mm) 182.5 182.5
6 Side port length of membrane assembly dia. (mm) 225 225
7 Packing area of membrane assembly (m²) 53 77
8 Wet weight of membrane assembly (Kg) 85 100
9 Transport weight of membrane module (Kg) 55 62
Ultra Filtration (UF) Solutions

FILPURE® ultrafiltration (UF) modules are manufactured using high-strength hollow-fiber membranes designed to provide reliable filtration performance, excellent chemical resistance, and long membrane service life.

Key features and benefits:

  • 0.03 µm nominal pore diameter — effectively removes bacteria, suspended particulates, and colloidal matter, helping protect downstream processes such as RO.
  • PVDF polymeric hollow fibers — provide high mechanical strength and excellent chemical resistance, supporting long-term membrane durability.
  • Hydrophilic PVDF fibers — provide good water wettability and facilitate effective membrane cleaning, helping maintain long-term filtration performance.
  • Outside-In flow configuration — provides high tolerance to feed solids and can help reduce the requirement for extensive pretreatment.
  • U-PVC module housing — provides a robust and corrosion-resistant housing while eliminating the need for costly external pressure vessels.

This UF modules are an ideal solution for medium- and large-capacity water-treatment systems, particularly systems with capacities above 50 m³/hr. They are suitable for a wide range of applications, including surface water treatment, industrial wastewater treatment, tertiary wastewater treatment, and pretreatment for reverse osmosis (RO) systems.

FILPURE® Inside-out Configuration UF series

Our inside-out configuration UF membranes are manufactured using modified PES (Polyethersulfone) chemistry, offering excellent chlorine tolerance, broad pH stability, and reliable long-term performance across demanding water and wastewater applications.

Small Footprint, Superior Performance

Small Footprint, Superior Performance

Our FILPURE Ultrafiltration (UF) modules utilize high surface area multi-channel capillary membranes engineered for high water flux. By maximizing packing density and flow rate, these compact modules reduce total footprint by 15–20% without compromising output.

Built for Durability

Built for Durability

Engineered with superior mechanical strength, FILPURE membrane capillaries prevent integrity failures and extend operating lifespan. Designed to withstand rigorous backwashing routines, they ensure reliable operations and continuous performance year after year.

Low Maintenance & High Efficiency

Low Maintenance & High Efficiency

Hydrophilic membrane surfaces prevent foulants from sticking tightly, enabling effortless cleaning during standard backwash cycles. This minimizes downtime, maintains high productivity, and significantly lowers chemical and operational costs over time.

MODEL FILPURE 1560 (45 m²) FILPURE (55 m²)
L 1850 2150
L1 1560 1860
L2 1420 1720
L3 1642 1942
d 200
W1 187
W2 240
Ultra Filtration (UF) Solutions

Technical Data Sheet FILPURE INSIDE-OUT CONFIGURATION SERIES

Module Specification
Parameters Description
Brand FILPURE
MOC of Membrane Modified PES
Capillary per fibre Heptabore
MOC of Body uPVC
MOC Cap uPVC
Potting Material Proprietary Epoxy
Flow In to out
Operating mode Cross Flow
ID of fiber capillary 0.85 mm
Preservative SMBS / Glycerine / water mixture
Operating Conditions
Parameters Description
Maximum Inlet Pressure 75 psi
Temperature Range 1–45 °C
Maximum TMP 45 psi
Maximum Feed Pressure 30 psi
Maximum Feed TSS# 100 mg/L
Maximum Instantaneous Chlorine 200 ppm, pH > 10
Maximum Cumulative Chlorine 200,000 ppm

Ready to Better Water Treatment Outcome?